T
← all calculators

Pump total head

Total dynamic head = static lift + friction loss (Hazen-Williams).

Friction loss4.83 m

Total head24.83 m

Estimate only — Hazen-Williams friction; C=130 (default). hf = 10.67·L·Q^1.852 / (C^1.852·D^4.87). Not a substitute for detailed design.